- Dispensing systems
- Cooling
- Cleaning
- Bar accessories
- Repair | Maintenance Beer cooling
- Offers
- Blog
Filters
Tapping fittings & dispensing system accessories for the catering trade
All kegs without a built-in tap need to be tapped in order to access the contents. Modern aluminium kegs, such as a 5-litre party keg or the keg used in the catering trade, either have a built-in tap or a special valve for connecting a keg tap head to the dispensing system.
In our extensive online shop, you will find everything you need for perfectly tapped beer - fromCO2 bottles to pressure reducers and beer stopcocks. We only offer items of professional quality:

Intermediate pressure regulator, Oxyturbo Major Plus 2-pipe 3 bar for CO2, N2 and mixed gas with wall bracket for mounting Connection right and left AG 5/8" 2x outlet AG 3/4" SK 427-002

Spanner for beer tap beer tap dispensing system tool SW Is required to dismantle / assemble the piston tap / compensator tap during cleaning.

Köpi tap head KEG tap head Draft with beverage catcher, stainless steel plunger Beverage connection R 5/8" Pressurised gas connection R 3/4" Non-return device Köpi tap head for cellar tapping for bar tapping (side outlet) low height A list of which KEG tap head belongs to which beer brand (brewery) can be found HERE You can find the corresponding beer screw connections HERE

König Pilsener tap head Micro Matic keg closure with beverage catcher, stainless steel plunger Beverage connection R 5/8" Pressurised gas connection R 3/4" Non-return valve König Pilsener tap head for cellar tapping for bar tapping (side outlet) low height A list of which KEG dispensing head belongs to which beer brand (brewery) can be found HERE ATTENTION: for this tap head you need a beer stopcock, see accessories above!!!

Kundo sensor unit for Co2 gas warning device for KundoCO2 gas detection system - use in the dispensing area The CO2 CONTROL gas detection system was developed in accordance with the requirements of the former TRSK 313 (Technical Requirements for Gas Detectors), now DIN6653-2 and the former TRSK 403 (requirements for installation, operation and maintenance), now BGR 228, and fulfils all legally required functions. Design: 1 room Consisting of: Sensor unit

Micro Matic beer stopcock CNS Beer stopcock CNS small, 5/8" female thread, 5/8" male thread, small design, for screwing onto KEG tap head

Beer stopcock bent made of stainless steel for screwing onto KEG tapping heads or tap spouts, with fixed spout. Beer tap, bent NW 7 mm bent NW 10 mm bent

Beer stopcock straight made of stainless steel for screwing onto KEG tapping heads or with fixed spout. Beer stopcock, straight NW 7 mm straight NW 10 mm straight

Micro Matic CO2 combi pressure reducer type Premium 3 and 7 bar with integrated safety valves, stopcock R 3/4" and R 1/2", with content indicator without nozzles and nuts. CO2 combination pressure reducer beer/AFG Micro Matic 3 and 7 bar On request with: wall plate + adapter for attaching the pressure reducer to the wall Wall plate

Micro Matic CO2 pressure regulator AFG 7 bar Type Premium Micro-Matic, 7 bar with integrated safety valve with stopcock without spout and nut. With content indicator. On request with: wall plate + adapter for attaching the pressure reducer to the wall

Micro Matic foam control fitting DFC 9500 Automatic foam control with the Micro Matic foam control fitting DFC 9500. The foam control fitting automatically recognises when the beer keg is empty and prevents beer foam from entering the beer line. Switches off the flow of the beer line as soon as the beer keg is empty, no loss due to empty beer lines, beer immediately restored after keg change. The devices guarantee that the beverage line remains filled with beer. Foam in the beer line? Buy DFC 9500 foam control valve now Foam control fitting simply to screw onto KEG or wall bracket. Available versions: Foam control fitting for screwing onto KEG for DFC 9500 Wall bracket for DFC 9500 Foam control fitting for wall mounting M. 2 x 5/8“ AG

Mk9 central unit for LogiCO2 gas detection system The Mk9 central unit is the centrepiece of the LogiCO2 gas detection system, making your workplace safe and secure. Equipped with high-quality cable material and shields, this central unit provides reliable monitoring of CO2 gases. With the Mk9 central unit for the LogiCO2 gas detection system, you are investing in the health and safety of your employees. The reliable monitoring of CO2 gases, easy installation and the possibility of customisation make this central unit an indispensable part of your workplace.

Mk9 central unit for LogiCO2 gas detection system, without accessories The Mk9 central unit for the LogiCO2 gas detection system offers you reliable protection against dangerous gas leaks in your home or commercial environment. This state-of-the-art device gives you full control over gas monitoring in your premises. The Mk9 central unit is the centrepiece of your gas detection system and ensures that you are alerted as soon as a gas leak is detected. Thanks to its intelligent functions, you are always informed about the CO2 values of all connected sensors and can see exactly which sensor is triggering the alarm on the display. The multilingual display of the central unit not only shows you alarm and error statuses, but also provides important information texts for the respective message. This allows you to react quickly and correctly to ensure your safety and that of your employees, customers or family. The Mk9 central unit also has an alarm memory that is automatically reactivated after a power failure. This means that no important alarms are lost and you can analyse the situation precisely.

analox Co2 Buddy mobile Co2 warning device Technical data mobile Co2 warning device: max. weight 70g Dimensions 74.4 x 62.6 x 33.3 mm LCD display alarm rechargeable battery (approx. 12h operating time per charge) Battery warning One-button operation Fresh air calibration low maintenance supported alarm configurations: 1.5% + 3%, 0.5% + 1.5%, 1.5% + 4% and 1% + 2% TWA alarm at 0.5% One-button operation IP 54 Visual, audible and vibrating alarm indication The internal battery can be easily recharged via a micro USB connection. This allows you to reach full power quickly and easily.

Mobus interface for LogiCO2 gas detection system The Mobus interface for the LogiCO2 gas detection system is the perfect accessory for permanently connecting your PC to the LogiCO2 software. This high-quality interface gives you access to all relevant measured values and statuses, such as alarms, from your CO2 safety system. The information can only be called up in read-only mode. Communication takes place via Modbus RTU (RS485) and enables seamless integration with external systems. Don't miss any more important data and rely on the reliability and efficiency of the Mobus interface for the LogiCO2 gas detection system.

Mounting panels made of stainless steel linen pattern, fully assembled, with Hiwi (Herzberg), intermediate pressure regulator battery SK 265-012. intermediate pressure regulator with ball shut-off valve separately for each line, connection made of CNS pipe, wall bracket, parking bracket for KEG tapping heads. Version including wall brackets with stopcock 2-pipe, 470 x 470 mm, 3-pipe, 770 x 470 mm, 4-pipe, 970 x 470 mm, 5-pipe, 1,230 x 470 mm, Delivery complete with 4/7/10 mm grommets, wireless at an extra charge.

Mounting panels made of stainless steel linen pattern, fully assembled, with Hiwi (Herzberg) , Intermediate pressure regulator battery SK 265-012. Intermediate pressure regulator with ball shut-off valve separately for each line, connection made of CNS pipe, wall bracket, parking bracket for KEG tapping heads. Version including wall brackets without stopcock 2-pipe, 470 x 470 mm, 3-pipe, 770 x 470 mm, 4-pipe, 970 x 470 mm, 5-pipe, 1.230 x 470 mm,

Mounting panels made of stainless steel linen pattern, fully assembled, with intermediate pressure regulator battery Micro-Matic SK 016-109. Intermediate pressure regulator with ball shut-off valve separately for each line, connection with CO2 hose, wall bracket CNS, Holder for KEG dispensing heads Version including wall brackets-CNS without stopcock 2-pipe, 470 x 470 mm, 3-pipe, 770 x 470 mm, 4-pipe, 970 x 470 mm, 5-pipe, 1.230 x 470 mm

Nitrogen (N2) pressure regulator 0-6/3 bar Connection right Outlet AG 3/4" Cylinder contents pressure gauge 0-400 bar SK 427-003

Nitrogen (N2) pressure reducer 1-line, 7 bar Connection right Outlet AG 1/2" Cylinder contents pressure gauge 0-400 bar SK 427-002

Nitrogen (N2) pressure reducer ODL, 0-6/3 bar or 0-10/7 bar, SK 215.16 with cylinder content indicator, grease-free ball shut-off valve without nozzle and nut. Nitrogen (N2) - pressure reducer ODL 3 bar (beer), On request with: wall plate + adapter for attaching the pressure reducer to the wall wall plate

Nitrogen cylinder with filling RAL grey with rotary valve, with TÜV approval Steel cylinder with base and protective cage Ø=108 mm, total length 430 mm Nitrogen cylinder - 2 L with base and cage
Contents: 2 Kilogramm (£57.43 / 1 Kilogramm)

Nitrogen pressure regulator N2 Premium Mirco-Matic type, 0-6/3 bar or 0-10/7 bar with cylinder content indicator, grease-free ball shut-off valve, without nozzle and nut. Nitrogen (N2) - Pressure regulator Micro-Matic Version: 3 bar (beer), 7 bar (AFG) On request with: Wall plate + adapter for attaching the pressure reducer to the wall Wall plate

O2 warning device sensor set Mk9 For extending your O2 detector set Mk9 4A or as a stand-alone device With the O2 warning device sensor set Mk9, you can expand your O2 detector set Mk9 4A and ensure reliable monitoring of the oxygen content in your environment. Thanks to its versatile functions, this sensor set is also suitable as a stand-alone detector. To use the O2 warning device sensor set Mk9 as a stand-alone device, you need the power supply 2363-4032, which is not included in the scope of delivery. Scope of delivery: CO2 detector Mk9 Horn/LED stroboscope including cable 10 m power/communication cable Plug lock 5 m signal cable 1 RJ45 1-4 plug, 1 RJ45 1-1 plug Manual + H/S sign With the O2 warning device sensor set Mk9, you can effectively secure your environment and create a safe working environment. Never miss any more warning signals and take the right measures in good time.